Seaward PrimeTest 100 PAT Tester
IET 5th Edition and BS EN50699 Compliant
The PrimeTest 100 portable appliance tester is battery powered and handheld to allow for fast and efficient testing with clear PASS/FAIL indication and test result values. A simple range of tests are selected at the push of a button to test earthed equipment, double insulated equipment or mains cords and leads.
– Selectable 250V/500V Insulation test
– Long lead test
– User selectable earth continuity limits
– Class II FE Test
1.000,00 د.إ
One of the most popular PAT testers in the UK, the PrimeTest 100 has built-in test sequences and smart technology to help you test a wide range of equipment quickly and easily.
Simply push one button to run through the pre-programmed test sequences for Class 1 equipment, Class 2 equipment or Leads. Connect the PrimeTest 100 to a power outlet and it will also check the socket wiring and mains voltage.
Its large digital display shows test result values, as well as a PASS or FAIL indication. The PrimeTest 100 is portable and battery powered, to help you work faster and more efficiently, with no need for a mains connection.
Seaward’s unique ‘ZAP’ technology ensures that earth continuity measurements are accurate in situations where other testers struggle to provide reliable measurements, such as measuring through rust, limescale and other surface contamination.
Built in Britain and used by 1,000’s of organisations every day.
| Feature | Details |
|---|---|
| Operation | Simple push-button operation |
| Test Sequences | Class I, Class II & Cord |
| Insulation Test | Selectable 250V / 500V |
| Earth Continuity Test | 200mA |
| Earth Continuity Limits | User selectable |
| Long Lead Test | Yes |
| Class II FE Test | Yes |
| IEC Lead Test | Yes |
| Alternative / Substitute Leakage Test | Yes |
| Mains Supply Check | Yes |
| Display | LCD with PASS/FAIL indication & test values |
| Power Source | Battery |
| Earth Continuity Technology | Seaward ZAP technology |
| Specification | Value |
|---|---|
| Earth Continuity Test Current | ±200mA DC |
| Earth Continuity Display Range | 0.00–19.99Ω |
| Earth Continuity Pass Values | 0.1Ω / 0.2Ω / 0.3Ω |
| Insulation Test Voltages | 250V / 500V DC |
| Insulation Resistance Display Range | 0.20–19.99MΩ |
| Insulation Pass Values | 1MΩ / 2MΩ |
| IEC Lead Test | Earth continuity, insulation resistance, live & neutral continuity and polarity |
| Class I Equivalent Leakage Test Voltage | 40V, 50Hz AC nominal |
| Class I Equivalent Leakage Range | 0.10–9.99mA |
| Class I Leakage Pass Values | 3.5 / 5.0mA |
| Class II Equivalent Leakage Test Voltage | 40V, 50Hz AC nominal |
| Class II Equivalent Leakage Range | 0.10–9.99mA |
| Class II Leakage Pass Values | 0.5 / 5.0mA |
| Power Socket Input Voltage Range | 230V +10% / −15% AC |
| Power Socket Indicators | Line-Earth, Line-Neutral & Neutral-Earth voltage |